| Standard Warranty | | 2 Year |
| Batteries | | 4 x Spill Proof Valve-regulated Lead Acid (VRLA) User-replaceable Hot-swappable |
| Manufacturer | | Liebert Corporation |
| Network Management | | SNMP Manageable Optional |
| Load Capacity | | 1500VA/1350W |
| Interfaces/Ports | | Serial USB |
| Temperature | | 32 F (0.0 C) to 104 F (40.0 C) Operating 5 F (-15.0 C) to 104 F (40.0 C) Storage |
| Plug/Connector Type | | NEMA 5-15P |
| Backup/Run Time | | 10 Minute 675W Half Load |
| Form Factor | | 2U Tower/Rack Mountable |
| Backup/Run Time | | 5 Minute 1350W Full Load |
| Parts Warranty/Labor | | 2 Year |
| Manufacturer Part Number | | PS1500RT3120XR |
| Additional Information | | Its flexible design allows the unit to be configured as a self-standing mini tower or to be rack-mounted within a 2U spaceIt is available in four capacities 1000, 1500, 2200 and 3000VA at 120VAC or 230VACConfigurable input voltage window allows the UPS to be properly matched to the incoming utility powerOptional external battery cabinets provide extended battery runtime for applications that require longer backup timeRotatable Display PanelThe UPS automatically adjusts to the input frequency, 50Hz or 60HzData line surge protectionAdvance early warning of UPS system statusFull sequenced battery testingHigher Output Power Factor (0.9)Reduced installation time and costs UPS is shipped with batteries connected and chargedAutomated shutdown software allows you to monitor communication between the UPS and a serverHalf Load > 10 minutes. 13-14 minutes typical |
| System Requirements | | Windows (98 and later) built-in power management functions provide monitoring of UPS status and manage the automatic orderly shutdown of the computer if a power outage everexceeds the battery capacity of the UPS |
| Manufacturer Website Address | | www.liebert.com |
| Additional Warranty Information | | Optional one-year and three-year extensions also available |
| Power Cord/Cable | | 10 ft |
| Humidity | | 0 to 90% Non-condensing Relative Humidity |
| Receptacles | | 6 x NEMA 5-15R - Battery Backup System |
| Input Voltage | | 110V AC |
| Dimensions | | 3.5" Height x 17.3" Width x 19.3" Depth |
| Battery Recharge Time | | 5 Hour |
| Brand Name | | Liebert |
| Input Voltage Range | | 83V AC to 159V AC Configurable 110V AC to 127V AC Configurable |
| Altitude | | 9842.52 ft Operating |
| Certifications & Standards | | Safety: UL 1778, c-UL ListedEmissions: FCC Part 15, Class ANetwork Surge: UL 497 BTransportation: ISTA Procedure 1A Certification |
| Shipping Dimensions | | 8.98" Height x 22.05" Width x 24.09" Depth |
| Emergency Power OFF | | Yes |
| Product Line | | PowerSure |
| Sound Emission | | <40 dB(A) |
| Output Voltage | | 83V AC to 159V AC Configurable |
| Frequency | | 50Hz 60Hz |
| Product Series | | PSI |
| Weight | | 62 lb |
| Voltage Handling | | 5% Output |
| Product Model | | XR |
| Shipping Weight | | 69.7 lb |
| Product Name | | PowerSure PSI XR 1500VA Tower/Rack-mountable UPS |
| Protection Type | | Lightning Surge |
| Product Type | | Line-interactive UPS |
| Waveform Type | | Sine Wave |
| Surge Energy Rating | | 570J |